[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: gEDA-dev: net and buses netnames



Carlos Nieves Ónega wrote:
Hi,
I think I've found a bug, unless anyone can give me a good reason for
this:
  - draw a bus or a net with an U shape.
  - double click on the first segment and set the netname to
"named_net1" in the multiple attribs window.
  - double click on any other segment:
    the previous assigned netname is not shown.

It seems that attributes are attached to net segments, instead of to the
net itself...

I can even set another different netname and both attributes are shown
(I know there is no current mechanism to check attributes), but I think
that at least the already assigned netname should be shown when you edit
the attributes of any other segment.
Regards,


Carlos

P.D.: Peter, have you considered this case in your datastructures
diagram?


attaching to net segments is actually a useful way for bundling a bunch of signals together into a bus. It also provides a useful shorthand for hooking up several instances in series.


-Dan